LIMIT | Everything can be measured 1
WORKSHOP MEASURING TOOLS Mierniki zegarowe USEFUL
FACTS ABOUT DIAL GAUGES Axial and tilting (lever) dial gauges are used for comparative measurements, which means that the indicated value is not an absolute value, but a differential (incremental) value. The deviation is read against the reference standard, or a combination of gauge blocks. Digital dial gauges make it possible to define an initial setting to permit indication of the absolute value, which simplifies the measurement. Dial gauges can be configured for internal measurements, or with a measuring stand. Gauges are used where access is difficult; for measuring holes, for example. It is possible to inspect irregularities or faults in a surface by running the feeler pin of the gauge along the surface. The gauge measuring tip moves along the circle arc, unlike the axial gauge where the movement is rectilinear. It is therefore necessary to keep the tiltable gauge measuring tip perpendicular to the surface being measured. Czujniki zegarowe, osiowe i uchylne (dêwigniowe), u˝ywane sà do pomiarów porównawczych, co oznacza, ˝e wskazywana wartoÊç nie jest wartoÊcià bezwzgl´dnà, lecz ró˝nicowà (przyrostowà). Odczytuje si´ odchy∏k´ w odniesieniu do wzorca albo kombinacji p∏ytek wzorcowych. W przypadku czujników zegarowych cyfrowych mo˝liwe jest ustawienie wst´pne, dzi´ki któremu wskazywana jest wartoÊç bezwzgl´dna, co upraszcza pomiar. Mierniki zegarowe mo˝na u˝ywaç skonfigurowane do pomiarów wewn´trznych, lub ze statywem pomiarowym. Czujniki uchylne stosuje si´ przy utrudnionym dost´pie, np. do pomiarów otworów. Prowadzàc dêwigienk´ pomiarowà takiego czujnika wzd∏u˝ linii równoleg∏ej do danej powierzchni mo˝na kontrolowaç jej nierównomiernoÊç lub uskoki. Ruch wierzcho∏ka pomiarowego czujnika uchylnego odbywa si´ po ∏uku okr´gu, w odró˝nieniu od czujnika osiowego, gdzie ruch jest prostoliniowy. Nale˝y zatem zwracaç uwag´, by wierzcho∏ek pomiarowy czujnika uchylnego by∏ utrzymywany jak najbli˝ej mierzonej powierzchni. Tabela tolerancji dla czujników zegarowych wg DIN 878. DIN 878 TABLE OF TOLERANCES FOR DIAL GAUGES (Tolerancje wg DIN 7168/1). Dopuszczalne odchy∏ki dla ró˝nych zakresów pomiarowych. (Temperatura odniesienia + 20°C). (Tolerances according to DIN 7168/1). Permissible deviations for various measuring ranges. (Reference temperature + 20 °C). Zakres pomiarowy Measuring range Odchy∏ka maksymalna, z b∏´dem ustalania Maximum deviation, with a determination error mm μm 0,4 mm 0.4 9 0,8 μm 9 9 30.8 129 35 12 14 5 14 10 17 10 17 y (0,1) 90° 135° 45° Limit. Czujnik zegarowy miniaturowy. Tarcza podzia∏ki obracana. Dodatkowa wskazówka dla pe∏nych mm. Wymienialna koƒcówka pomiarowa. Bez ucha mocujàcego. Tolerancja wg DIN 878. (-1,0) 180° 0° x Nr art............................. Oznaczenie podzia∏ki .............. 225° 10390 Zakres pom. ...................... mm Dzia∏ka ........................... mm 270° -0106 5 315°0.01 0-50, 50-0 1 obrót wskazówki = ............... mm 0.5 Âredn. tarczy...................... mm 40 Âredn. zamocowania .............. mm 8 34 | Wymiar A......................... mm 38 Wymiar B......................... mm 48 Wymiar C......................... mm 42 Wymiar D......................... mm 14 Wymiar F......................... mm 14 Wymiar G ........................ mm 13 Wymiar H......................... mm 40 Wymiar J ......................... mm (0,-1) 7 (1,0) Mierniki zegarowe